Extron RCP 401 Series are remote control button panels that allow remote operation of the SMP 401. User-friendly record, pause, stop, and mark buttons enhance the recording experience. Manage and save files directly to thumb drives or external portable drives through a USB port that supports writing speeds up to 5 Gbps. It also features buttons for swap and layout preset recall functions, streamlining the creative workflow. Status lights and audible alerts keep users informed of SMP 401 recording status. The RCP 401 Series includes a USB-C control cable for easy, out-of-the-box connection to the SMP 401. It comes in decorator-style, MK, and EU versions. RCP 401 Series panels include black and white faceplates for a wide range of environments. MK model is available in white only.
Copy TextCopied!An error occurred. Please try again later.
RCP 401 Decorator-Style Remote Control Panel for SMP 400 Series Products
Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include both white and black faceplates.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 401 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 (60-1868-01); no alternates or equals
RCP 401 Decorator-Style Remote Control Panel for SMP 400 Series Products
Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include both white and black faceplates.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 401 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 (60-1868-01); no alternates or equals
RCP 401 MK mount Remote Control Panel for SMP 400 Series Products
Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include a white faceplate only.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 MK (60-1868-22); no alternates or equals
RCP 401 MK mount Remote Control Panel for SMP 400 Series Products
Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include a white faceplate only.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 MK (60-1868-22); no alternates or equals
RCP 401 EU mount Remote Control Panel for SMP 400 Series Products
Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include both white and black cover plates.
Device shall be compatible with Extron’s Flex55 mounting systems.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 EU (60-1868-32); no alternates or equals
RCP 401 EU mount Remote Control Panel for SMP 400 Series Products
Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
Connection Requirements
USB Requirements
Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
Provide one front accessible USB type A receptacle
Support 12V power connection
Provide one rear captive screw connection for 12VDC power
Mounting requirements
Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
Device shall include both white and black cover plates.
Device shall be compatible with Extron’s Flex55 mounting systems.
Cabling requirements
Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
Shall include backlit rubberized button panel interface.
Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
Buttons shall feature two levels of illumination, dim and bright
Buttons shall illuminate brightly when active, and have the ability to flash
Record button shall feature red illumination during recording.
Record button shall have a raised bump to allow user to located it with low visibility
Shall include status LED indicators
Device shall have a red and green status LED indicator for alarm and button press activity
Device shall have a green LED for USB storage indicating:
Off – no storage is detected, or the location is not configured.
Green solid – Storage is detected, and the port is configured.
Green blink – Storage is being written, or accessed.
Shall include audible warning - buzzer.
Device shall have an internal buzzer that sounds in conjunction with the status LED.
Shall include a means to lock out the front panel controls.
When enabled, the buttons flash 3 times when any one button is pressed.
Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
Shall meet regulatory compliances
Shall be certified to meet safety compliances under CE, c-UL, and UL
Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
Shall comply with requirements of RoHS and WEEE
Shall provide three year parts and labor warranty
Approved device shall be the Extron RCP 401 EU (60-1868-32); no alternates or equals
Add Item to Cart
Order Message Number
Part #
Note: Extron products using the Universal AC Outlet accept a number of different AC plug types. Before use, ensure that the device meets all regulatory requirements for your region and complies with all applicable local safety and electrical codes and standards.
Current Total:
RCP 401 Series -
Annotation Graphics Processor
To view this page ensure that Adobe Flash Player version
11.0.0 or greater is installed and enabled.
Share this item via Email
RCP 401 Series
Remote Control Panels for SMP 401
Please enter a valid e-mail address.
Thank you. Your email has been sent.
An error occurred while sending your e-mail. Please try again later.
Please upgrade your browser for the full Extron experience
You are using [browser] [version] on [os]
It looks like you may be using an outdated browser that we no longer support. Extron uses the latest technology to make its website faster and easier to use. For the best experience, please use one of these supported browsers: