XPA 2001 Series |
|
Audio |
Voltage gain | |
XPA 2001-70V | 57x (35 dB) |
XPA 2001-100V | 81x (38 dB) |
Stereo channel separation | >75 dB @ 1 kHz |
CMRR | 75 dB @ 1 kHz (typical) |
|
Audio input |
Number/signal type | 1 stereo or 2 mono, balanced/unbalanced |
Connectors | (1) 3.5 mm captive screw connector, 5 pole |
Impedance | >10k ohms unbalanced/balanced, DC coupled |
Nominal level | +4 dBu (1.23 Vrms), balanced |
Maximum level | +20 dBu (7.75 Vrms), balanced |
Input sensitivity | +4 dBu (1.23 Vrms) if driven by one input -2 dBu (0.615 Vrms) if both inputs are summed |
Input signal detection threshold | -40 dBu ±3 dB, balanced |
NOTE | 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu |
|
|
Audio output |
Number/signal type | |
XPA 2001-70V | 1 mono, 70 V line |
XPA 2001-100V | 1 mono, 100 V line |
Connectors | (1) 5 mm screw lock captive screw connector, 2 pole |
NOTE | These connectors accept wires of 22 AWG to 12 AWG. |
|
Load impedance |
XPA 2001-70V | 25 ohms minimum |
XPA 2001-100V | 50 ohms minimum |
Amplifier type | Class D |
Output power |
XPA 2001-70V | 200 watts rms, 70 V, 1 kHz, <0.1% THD |
XPA 2001-100V | 200 watts rms, 100 V, 1 kHz, <0.1% THD |
Frequency response | 20 Hz to 20 kHz, ±1 dB |
THD + Noise | <0.1% @ 1 kHz at 3 dB below clipping |
S/N | 100 dB, 20 Hz - 20 kHz, unweighted |
Damping factor | |
XPA 2001-70V | >100 @ 25 ohms |
XPA 2001-100V | >100 @ 50 ohms |
High pass filter | 80 Hz, 12 dB per octave rolloff (switch selectable) |
|
Control/remote — amplifier |
Control port | (1) 3.5 mm captive screw connector, 5 pole |
Pin configurations | |
DC volume control (analog) | Pin 1 = +10 VDC, 50 mA (max.), pin 2 = volume/mute (variable voltage), pin 3 = GND |
Volume control voltage range | 0 V (mute) to 10 V (maximum volume) |
Standby power control (contact closure) | Pin 4 = GND, pin 5 = standby |
|
General |
Power supply | Internal Input: 100-240 VAC, 50-60 Hz |
Power consumption and thermal dissipation | |
XPA 2001-70V
|
115 VAC, 60Hz |
230 VAC, 50Hz |
AC Line
Current |
AC Power
Consumed |
Thermal
Dissipation |
AC Line
Current |
AC Power
Consumed |
Thermal
Dissipation |
Condition |
A |
W |
W |
BTU/hr |
A |
W |
W |
BTU/hr |
Active (1/8 power), all
channels driven |
70 V |
0.4 |
42.2 |
17.2 |
59 |
0.3 |
43.3 |
18.3 |
62 |
Quiescent (idle) |
0.2 |
9.5 |
9.5 |
32 |
0.1 |
10.2 |
10.2 |
35 |
Standby |
<0.1 |
<1 |
<1 |
<3 |
<0.1 |
<1 |
<1 |
<3 |
|
XPA 2001-100V
|
115 VAC, 60Hz |
230 VAC, 50Hz |
AC Line
Current |
AC Power
Consumed |
Thermal
Dissipation |
AC Line
Current |
AC Power
Consumed |
Thermal
Dissipation |
Condition |
A |
W |
W |
BTU/hr |
A |
W |
W |
BTU/hr |
Active (1/8 power), all
channels driven |
100 V |
0.4 |
43.7 |
18.7 |
64 |
0.4 |
44.8 |
19.8 |
68 |
Quiescent (idle) |
0.1 |
11.9 |
11.9 |
41 |
0.1 |
11.9 |
11.9 |
40 |
Standby |
<0.1 |
<1 |
<1 |
<3 |
<0.1 |
<1 |
<1 |
<3 |
|
Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
Cooling | Convection, no vents, with internal heat sinks |
Protection | Clip limiting, thermal, short circuit, DC output |
Indication | Limiter/Protect LED indicates the onset of clip limiting, thermal cycling, or a short circuit |
Mounting | |
Rack mount | Yes, with optional 1U rack shelf |
Enclosure type | Metal |
Enclosure dimensions | 1.7" H x 8.7" W x 9.5" D (1U high, half rack wide) (4.3 cm H x 22.1 cm W x 24.1 cm D) |
Product weight | 2.5 lbs (1.1 kg) |
Vibration | ISTA 1A in carton (International Safe Transit Association) |
Regulatory compliance | |
Safety | BSMI, CCC, CE, c-UL, GS, KC Mark, PSE, S Mark, UL UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release; meets UL 60065, IEC 60065, and BSEN 60065 for AV equipment. |
EMI/EMC | CE, CISPR 22 Class B, C-tick, FCC Class B, ICES, KC, VCCI Class B |
Environmental | Complies with the appropriate requirements of ENERGY STAR® (ENERGY STAR qualified amplifier), EU code of conduct, RoHS, WEEE |
Product warranty | 3 years parts and labor |
Everlast power supply warranty | 7 years parts and labor |
NOTE | All nominal levels are at ±10%. |
|
NOTE | Specifications are subject to change without notice. |
|
(5675-D25) |