MLC 62 RS CC

MediaLink Controller for Cable Cubby Cable Access Enclosures
Key Features
  • Designed to mount in most Cable Cubby® cable access enclosures
  • Customizable backlit buttons
  • Two-space MAAP opening for cable pass-through or AV connectivity
  • Convenient three split-ring hole pass through plate
  • Unidirectional RS-232 and configurable IR ports for universal display control
  • Two relays
The Extron MLC 62 RS CC
Model Version Description Part #
 MLC 62 RS CC IR and RS-232 for CC 650 UT/1200/1202/1400/1402 60-1005-52

The Extron MLC 62 RS CC is a MediaLink® controller housed in a versatile mounting bracket designed to integrate into Cable Cubby® cable access enclosures. This easy-to-use keypad controller provides popular AV control functions, including power, input switching, and volume. It has eight backlit soft touch buttons and features a variety of ports, including RS-232 serial and IR ports for universal display control, two relays for control of lighting, screen settings, and other device functions, and a digital input. A convenient split-ring hole pass through plate provides access to cables from the Cable Cubby cable access enclosure.

Features

  • Designed to mount in most Cable Cubby® cable access enclosures — Provides easy access to room control functions or stays concealed when not in use.
  • Customizable backlit buttons — Standard buttons available for power on, power off, volume up, volume down, and source selection. A variety of pre-labeled buttons are included, allowing the controller to be easily customized to suit the application. Backlit buttons provide ease of use in low-light environments.
  • Two-space MAAP opening for cable pass-through or AV connectivity — Provides convenient access for room connectivity
  • Convenient three split-ring hole pass through plate — Two 3/8” holes and one ¼” hole provide access to cables.
  • Unidirectional RS-232 and configurable IR ports for universal display control — The MLC 62 RS CC has a dedicated port for communicating with virtually any projector or flat panel display via unidirectional RS-232 or IR control. Display control drivers can be downloaded from the Extron Web site and used to configure the controller.
  • Two relays — Enable control of lighting, screen settings, and other device functions.
  • Digital input — Allows for a connection with a variety of devices, such as sensors, switches, and relays.
  • Easy-to-use configuration software provides fast and easy setup
  • Thousands of Extron certified, ready-to-use device drivers
  • IR learning capability — The MLC 60 Series Configuration Program is able to capture IR codes from a device’s handheld remote control.
  • Volume adjustment buttons with LED level indication — Individual up and down buttons for audio level control with five LEDs that indicate current audio settings.
  • Pre-printed buttons included for controller customization — Buttons printed with various labels are supplied and can be changed individually to match the control application.
  • Macro capability — Any button can be configured to execute multiple actions through the serial and IR control ports. For instance, the touch of a single button could trigger commands to turn on the display, select the display's RGB input, and trigger a relay.
  • Toggle mode — Provides additional flexibility by allowing two different sets of commands to be executed with alternating presses of a button.
  • Source buttons offer a choice between a single or dual function setup by simply swapping out the bezel and buttons — In applications where only a single function is necessary for one source device, a dual function bezel and button can be replaced with a single function bezel and button.
  • Built-in speaker — Provides audible feedback when buttons are pressed to confirm user action.
  • Inactivity timer for display shutoff — Adjustable timer controls automatic shutdown to conserve energy, prevent plasma burn-in, or extend projector's lamp life.
  • Front panel security lockout — If the MLC 62 RS CC is installed in an unsecured environment where easy access is not desirable, a security lockout feature may be implemented to lock out all front panel controls.
  • Activity LED to indicate various controller states — Bi-color, green and red LED indicates button presses, the transfer of data, front panel lockout, and other actions.
  • Mini USB configuration port — Provides configuration interface through a laptop or PC.
  • Pluggable captive screw connector — Provides quick and easy connection to the controller for easy installation and troubleshooting.
  • Available in black
  • External Extron Everlast™ power supply included — Provides worldwide power compatibility with high-demonstrated reliability and low power consumption
  • Extron Everlast Power Supply is covered by a 7‑year parts and labor warranty
INCLUDED ACCESSORIES
  Captive Cable Kit with Three Split-Ring Holes Double Space MAAP - Black: Captive Cable Kit Includes flexible split-ring plate, one small 0.25” (.64 cm) and two medium 0.375” (.95 cm) openings with corresponding plugs 70-1082-01
OPTIONAL ACCESSORIES
  MLC 62 Button Kits Button Options for MLC 62 Series MediaLink Controllers
  USB CFG Cable USB A Male to USB Mini B Male Configuration Cable
  IR Emitter and Shield Kits IR Emitter Kits for Extron Products With IR Output
SIMILAR PRODUCTS
  MLC 62 RS D MediaLink Controller with RS-232 Control - Decorator-Style Wallplate
  MLC 62 RS EU MediaLink Controller for EU Junction Boxes
  MLC 62 RS MK MediaLink Controller for MK Junction Boxes
  MLC 64 RS VC D MediaLink Controller with Volume Control Knob - Decorator-Style Wallplate

Specifications

MLC 62 RS CC
General
   Power supply External, included
Input: 100-240 VAC, 50-60 Hz
Output: 12 VDC, 0.5 A, 6 watts
   Power input requirements  12 VDC
   Power consumption 
      MLC 62 RS models 
         Device  2.1 watts
         Device and power supply  2.5 watts
   Cooling Convection
   Thermal dissipation 
      MLC 62 RS models 
         Device  7.0 BTU/hr
         Device and power supply  8.4 BTU/hr
   Ambient temperature/humidity Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Mounting Mounts into Cable Cubby® 1202 and 1402 enclosures
   Material Metal
   Dimensions 4.2" W x 2.4" D x 3.9" H
(107 mm W x 61 mm D x 100 mm H)
       
   Product weight  1.0 lb (0.5 kg)
   Vibration  ISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance CE, c-UL, UL, C-tick, FCC Class A, ICES, VCCI Class A, RoHS, WEEE
Section 508 of the Rehabilitation Act (29 U.S.C. 794d)
   Product warranty 3 years parts and labor
   Everlast power supply warranty 7 years parts and labor
Control — host ports
   Serial control port 1 bidirectional RS-232 on a 3.5 mm captive screw connector, 3 pole
   Baud rate and protocol 9600 baud, 8 data bits, 1 stop bit, no parity
   Serial control pin configuration Pin 1 = Tx, pin 2 = Rx, pin 3 = GND
   USB control ports 1 side panel female mini USB B
   USB standards USB 2.0, low speed
   IR learning frequencies 30 kHz to 60 kHz
   IR learning distance 4" (10 cm) to 14" (36 cm) from the receiver (on side panel)
   Program control Extron configuration program for Windows®
Extron Simple Instruction Set (SIS)
Serial control
   Display control port (1) 3.5 mm captive screw connector, 2 pole for unidirectional RS-232 control (±5 V)
   Baud rate and protocol (RS-232) 9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits; 1 stop bit; no parity (default), or even or odd parity
IR control
   IR control port (1) 3.5 mm captive screw connector, 2 pole (transmit only)
TTL level (0 to 5 V) modulated infrared control from 30 kHz up to 60 kHz, or ±5 V
RS-232 control
*IR/serial ports are configurable via software, serial communication is the default.
   Baud rate and protocol 9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits; 1 stop bit; no parity (default), or even or odd parity
Relay control
   Number/type 2 momentary or latching (configurable via software)
   Connector (1) 3.5 mm captive screw connector, 3 pole
   Contact rating 24 V, 1 A
Digital input control
   Number/type 1 digital input (configurable)
   Connector (1) 3.5 mm captive screw connector, 2 pole
   Digital inputs 
      Input voltage range 0-24 VDC
      Input impedance 12k ohms
      Programmable pullup 2k ohms to +5 VDC
      Threshold low to high >1.5 VDC
      Threshold high to low <1.0 VDC
 NOTE     All nominal levels are at ±10%.
 NOTE     Specifications are subject to change without notice.
(4514-D2)
Shipping Dimensions and Weights
    Part # Height Width Depth Weight
    60-1005-52 3.0" (7.6 cm) 7.5" (19.1 cm) 10.5" (26.7 cm) 1.96 lbs (0.89 kg)

Diagram

MLC 62 RS CC with eight button bezel Diagram

Panel Drawing

MLC 62 RS CC Panel Drawing